The GE Brivo CT315 is a compact and efficient CT imaging solution developed by GE Healthcare to make high-quality diagnostic imaging more accessible to healthcare providers of all sizes. Designed with cutting-edge GE CT technologies and a patient-centered philosophy, the Brivo CT315 delivers reliable performance, excellent image clarity, and optimized workflow efficiency—all within a small footprint ideal for clinics and facilities with limited space.Ultra-compact footprint for easy installation in limited spaces, providing flexibility for hospitals, clinics, and diagnostic centers. High Image Quality: Incorporates GE’s advanced spectral calibration technology to ensure consistent image uniformity and sharpness across the entire field of view. Low Radiation Dose: Features GE’s OptiDose and Auto mA technologies to maintain diagnostic accuracy while minimizing radiation exposure in accordance with ALARA principles. Streamlined Workflow: User-friendly interface and simplified operation enable fast scanning, high patient throughput, and efficient clinical workflow. Versatile Applications: Supports a wide range of clinical needs, including general diagnostics, cardiovascular assessment, oncology evaluation, and emergency imaging. Helical Scanning Capability: Continuous volume data acquisition enables detailed 2D and 3D reconstructions, such as Multi-Planar Reconstruction (MPR) and Virtual Endoscopy.
Key Features
Covers major subsystems including mechanical, imaging, power, and cooling modules.
Provides component functions and compatibility notes for quick fault diagnosis.
Focuses on replaceable modules (RUs/FRUs) and high-wear components to reduce downtime.
Parts List
# | Part Name | Part Number | Description | Key Features |
---|---|---|---|---|
1 | X-ray Tube | Example / To be confirmed | High-voltage tube assembly that generates X-rays and controls radiation dose. | High stability, cooling requirement, must match system power and interface. |
2 | Detector Module | Example / To be confirmed | Converts X-ray signals into electrical signals, determining image quality and uniformity. | Modular design, fast response, requires spectral calibration compatibility. |
3 | High-Voltage Generator | Example / To be confirmed | Supplies stable high-voltage power to the X-ray tube, controlling tube current and voltage. | Stable output, overcurrent/overvoltage protection, compatible with Performix tube. |
4 | Gantry Assembly | Example / To be confirmed | Includes the rotating frame, drive mechanism, and insulation system. | High mechanical precision, requires balance calibration and professional installation. |
5 | Patient Table Assembly | Example / To be confirmed | Supports and positions patients precisely during scanning, driven by motorized system. | High positioning accuracy, load capacity compliant, includes motor and control module. |
6 | Slip Ring | Example / To be confirmed | Transfers electrical power and signals during continuous gantry rotation. | Low noise, wear-resistant, requires periodic inspection and lubrication. |
7 | Cooling System Components | Example / To be confirmed | Provides cooling to the X-ray tube and generator, maintaining safe operating temperature. | Stable flow, high-temperature resistance, filters and seals are consumables. |
8 | Power Supply Module | Example / To be confirmed | Delivers regulated power to imaging console, host, and subsystems. | Overload protection, matches rated system power requirements. |
9 | Image Workstation / Reconstruction Unit | Example / To be confirmed | Handles image reconstruction, post-processing, and DICOM data transfer. | Linux-based system, supports MPR/3D reconstruction, requires software updates. |
10 | Collimator Assembly | Example / To be confirmed | Shapes and limits the X-ray beam to reduce scatter and optimize dose distribution. | High adjustment accuracy, synchronized with scan protocols. |
11 | Interface / Communication Modules | Example / To be confirmed | Provides interconnection between HIS/PACS systems and internal CT subsystems. | DICOM compliant, includes Ethernet and I/O interface boards. |
12 | UPS / Backup Power | Example / To be confirmed | Ensures safe system shutdown or temporary operation during power loss. | Capacity must meet site requirements and local power conditions. |
13 | Calibration Phantoms & Kits | Example / To be confirmed | Used for image uniformity, dose, and geometric accuracy testing. | Essential for routine QC and compliance documentation. |
14 | Cabinet Fans / Filters | Example / To be confirmed | Provide ventilation and dust filtration for electrical cabinets. | Consumable components, should be cleaned or replaced regularly. |
Part Detail
Part Description | Part Number (P/N) |
---|---|
MX135 X-Ray Tube | DA135 |
Inverter Mid Power Assembly, RoHS | 5126989-2 |
Aperture Assembly with Cables | 2257217 |
P2040AA CT/E-T Detector Assembly | 2321043 |
Aperture Assembly with Cables | 2257217-5 |
Dunlee DA135CT/E Tube | 989605580800 |
TGPL Board for Linglong System | 5310990-2 |
Low Voltage Power Supply (LVPS) 3 Phase v5 RoHS | 2212166 |
MX135 CT TH.1.1 GREEN | D3161T |
CT E-T Detector Assembly RoHS | 5341043 |
Low Voltage Power Supply (LVPS) 3 Phase v5 RoHS | 5126988-3 |
Microsensor | U0002PB |
RMT Board Assembly | 2301670-2 |
MX135 CT Tube | 5363417 |
Inverter Mid Power Assembly, RoHS | 5126989 |
Low Voltage Power Supply (LVPS) 3 Phase v5 RoHS | 5126988-2 |
Jedi NP Plus v1.5 Generator | 2227720 |
Low Voltage Power Supply (LVPS) 3 Phase v5 RoHS | 2212166-2 |
Economy SlipRing Detector Assembly | 2245151 |
Jedi NP Plus v1.5 Generator | 2227720-2 |
LL Data Acquisition System (DAS) Power Supply Assembly | 5323970 |